#913 new task

Use E+ Coil:Cooling:DX:VariableSpeed

Reported by: jwinkler Owned by: jwinkler
Priority: normal Component: Modeling - General
Version: 3.0.0.0 Keywords:
Cc: nmerket, ewilson

Description

Update the new Coil:Cooling:DX:VariableSpeed which supports multi-speed air conditioners and furnaces. Eliminates the use of a work around causing errors in E+ 8.2

Attachments (5)

1.idf (975.6 KB) - added by jwinkler 4 years ago.
1.xlsx (169.1 KB) - added by jwinkler 4 years ago.
1_var_speed.idf (976.1 KB) - added by jwinkler 4 years ago.
1_var_speed.xlsx (160.0 KB) - added by jwinkler 4 years ago.
1_sched.csv (662.8 KB) - added by jwinkler 4 years ago.

Change History (12)

comment:1 Changed 4 years ago by jwinkler

  • Version changed from 2.3.0.0 to 0.1 Waiting on Others

There is a bug in E+ v8.2 when using a Coil:Cooling:DX:VariableSpeed object with a gas furnace preventing us from using the model. The impact is on the supply fan energy.

I sent the following text in an email to Edwin:

The issue is with the heating air flow rate. When the variable speed cooling coil is used, the cooling airflow rate is being used in heating mode. The heating airflow rate specified in the unitary object is not being used. In the attached Excel files I’ve highlighted several hours when the runtime fraction of the heating coil equals 1. You’ll see in 1_var_speed.xlsx that the airflow rate is equal to the cooling air flow rate. The results are correct in 1.xlsx.

This has a significant impact on the fan energy.

comment:2 Changed 4 years ago by shorowit

  • Cc nmerket added

Can you attach the files here? Also, have we heard back from the E+ folks about this?

Changed 4 years ago by jwinkler

Changed 4 years ago by jwinkler

Changed 4 years ago by jwinkler

Changed 4 years ago by jwinkler

Changed 4 years ago by jwinkler

comment:3 Changed 4 years ago by jwinkler

The attached two IDFs are identical with the exception of the cooling coil type. 1.idf uses the Coil:Cooling:DX:SingleSpeed and 1_var_speed.idf uses Coil:Cooling:DX:VariableSpeed. A gas furnace and the AirLoop:UnitaryHeatCool object are used in both files.

comment:4 Changed 3 years ago by shorowit

  • Cc ewilson added
  • Version changed from 0.1 Waiting on Others to 2.5.0.0

Jon will attempt to switch our multi-speed and variable-speed ACs over to this model, which should allow us to remove our workaround for natural gas furnaces.

comment:5 Changed 3 years ago by shorowit

  • Version changed from 2.6.0.0 to 2.5.0.0

Jon, is this still on your radar?

Related to #973.

comment:6 Changed 3 years ago by jwinkler

Yes, I've been working on this.

comment:7 Changed 3 years ago by shorowit

  • Version changed from 2.5.0.0 to 2.6.0.0